title: "Connecting a signature pad to portier Vision 5"
description: "Which signature pad portier Vision 5 works with, how to connect it over USB, and what to do when portier Vision 5 runs on a server over Remote Desktop."
url: https://help.portiervision.com/en/articles/131-connecting-a-signature-pad-to-portier-vision-5
collection: "Integrations & IT Setup"
updated: 2026-11-24
language: en
alternates: [de, fr]
---

# Connecting a signature pad to portier Vision 5

Which signature pad portier Vision 5 works with, how to connect it over USB, and what to do when portier Vision 5 runs on a server over Remote Desktop.

A signature pad lets the key holder confirm an issue or a return directly in portier Vision 5. The signature is saved with the booking. How to issue a key is described in [Key Issuing](https://help.portiervision.com/en/articles/68-key-issuing.md).

## Which pad to use

portier Vision 5 works with signature pads from signotec. The signature screen is laid out for the signotec Sigma. We recommend the Sigma with a USB connection.

## Connecting the pad

Connect the pad over USB to the PC that runs portier Vision 5. The program looks for the pad on that computer only, first on the USB ports, then on the serial (COM) ports.

portier Vision 5 does not find a pad over the network. There is no setting for a pad's IP address. This also applies to pads that have a network port of their own.

## Installing the driver

portier Vision 5 does not include the driver for the pad. On the PC with the pad, install signotec's signoPAD API for Windows, in the 32-bit variant. Run the setup as administrator, then restart portier Vision 5.

-   [signoPAD API for Windows, 32-bit, version 9.0.1](https://backend.signotec.com/wp-content/uploads/2026/01/signoPAD-API_9.0.1_32Bit.exe), direct download from signotec (140.1 MB, as of November 2026)
    
-   [signoPAD API page at signotec](https://www.signotec.com/en/help-centre/signopad-api/), which always lists the latest version
    

You need the 32-bit variant on 64-bit Windows as well, because portier Vision 5 is a 32-bit program. If only the 64-bit variant is installed, add the 32-bit one.

## Remote Desktop and terminal servers

When you work over Remote Desktop, portier Vision 5 runs on the server. That is also where it looks for the pad, not on the PC in front of you.

If the pad cannot be connected there, install portier Vision 5 directly on the PC at the key desk and connect the pad to that PC over USB. The database stays on the server. The PC needs a connection to the database, TCP 1433 for Microsoft SQL Server or TCP 3050 for Firebird, plus the other ports and domains in section 5 of the [system requirements](https://help.portiervision.com/en/articles/111-system-requirements-and-performance-guidance-for-portier-vision.md). How to install portier Vision 5 and connect it to the database is described in [Install and set up portier Vision 5](https://help.portiervision.com/en/articles/110-install-and-set-up-portier-vision-5.md).

## Signing without a pad

With the KeyOnTheGo app, the key holder signs on a smartphone or tablet. How it works is described in [KeyOnTheGo Mobile App](https://help.portiervision.com/en/articles/75-keyonthego-mobile-app.md) and [KeyOnTheGo Key Assignment](https://help.portiervision.com/en/articles/76-keyonthego-key-assignment.md).

## If the pad is not detected

-   **"Class not registered"** means the 32-bit signoPAD API is missing. Install it as described above.
    
-   **"There is no device with this device ID!"** means portier Vision 5 finds no pad on this computer. Check the USB cable, and check that portier Vision 5 runs on the computer the pad is connected to. A pad on the network, or on the PC you use to connect over Remote Desktop, gives the same message.